Set Appliance State:
Mains Power Off
Function selector in CH position
All heating controls calling
All heating controls calling
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Observation:
Wait at least 5 seconds after power On.
Remove diverter valve motor/actuator.
Is the actuator in the CH position spindle fully forward?
Note:
When in CH position brass spindle is within a couple of mm below the level of the plastic case.
| Isolate Mains Power to appliance as per TOP's P4 |
Remove diverter valve motor/actuator.
Is the actuator in the CH position spindle fully forward?
Note:
When in CH position brass spindle is within a couple of mm below the level of the plastic case.
Isolate as per TOPs P4
and refit as necessary