Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector X4 at the PCB
Measurement:
Measure the resistance between pins 1 and 2 (black wires) at the disconnected connector.
Resistance should be short circuit.
Note:
Remember if a white PCB is fitted
X4 is in a different position.
Resistance should be short circuit.
Note:
Remember if a white PCB is fitted
X4 is in a different position.

Isolate as per TOPs P4
and refit as necessary