Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect connector at gas valve

Measurement:

Check for continuity between the blue, black and brown wires of the gas valve plug to the wires of corresponding colour, in turn, at J3 connector on the ignition PCB.
Also inspect the overall harness condition.