Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Attach temperature probes to the flow and return pipes as indicated
DHW Temperature Selector set to MAX
Set flow rate to approximately as per table
DHW Temperature Selector set to MAX
Set flow rate to approximately as per table
Gas On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Reset appliance as necessary.
Allow the burner to light and establish.
Monitor the temperature differential between the
flow and return pipes for at least 2 minutes.
The differential should be approximately 25°C or lower.
Allow the burner to light and establish.
Monitor the temperature differential between the
flow and return pipes for at least 2 minutes.
The differential should be approximately 25°C or lower.