Set Appliance State:
Mains Power Off
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
After self test has completed, place the boiler into installer mode 1 (flame current).
Apply a DHW demand and observe the display, when the burner ignites the number displayed should be greater than 5.
Note.
1. For information on how to enter installer mode CLICK HERE
2. Once in installer mode the information will be displayed for approximately 1 minute (returns to normal display) re-enter mode if required.
Apply a DHW demand and observe the display, when the burner ignites the number displayed should be greater than 5.
Note.
1. For information on how to enter installer mode CLICK HERE
2. Once in installer mode the information will be displayed for approximately 1 minute (returns to normal display) re-enter mode if required.