Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Drain primary system water from boiler until no pressure is in system
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Measurement:

With no pressure in system measure the DC voltage across the red lead
(pressure sensor connector) and terminal 2 (blue) main terminal block.
Expected voltage approximately 0.0 Vdc.
Note.
1. Terminal 1 of main terminal block is the top connection when facing appliance front.
2. A fault code may be displayed due to no system pressure, this will not affect test results.