Set Appliance State:
Mains Power Off
DHW Demand
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for DC voltage across the red lead (DHW turbine connector) and terminal 2 (blue) main terminal block.
Expected voltage approximately 1.8 - 2.5 Vdc.
Note:
Due to the positioning of the DHW turbine it can be difficult to
obtain a reading. Ensure a good connection is made.
Expected voltage approximately 1.8 - 2.5 Vdc.
Note:
Due to the positioning of the DHW turbine it can be difficult to
obtain a reading. Ensure a good connection is made.

Isolate as per TOPs P4
and refit as necessary