Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector from gas valve.
Measurement:
Test 1.
Measure for resistance across the outer terminals of the gas valve.
Expected resistance approximately 4.4 Kohms.
Note.
Ensure a good connection is made or misdiagnosis will occur.
Test 2.
Measure for resistance across one of the outer terminals & center terminal of the gas valve.
Expected resistance greater than 1 Mohm.
Note.
Ensure a good connection is made or misdiagnosis will occur.
Measure for resistance across the outer terminals of the gas valve.
Expected resistance approximately 4.4 Kohms.
Note.
Ensure a good connection is made or misdiagnosis will occur.
Test 2.
Measure for resistance across one of the outer terminals & center terminal of the gas valve.
Expected resistance greater than 1 Mohm.
Note.
Ensure a good connection is made or misdiagnosis will occur.

Isolate as per TOPs P4
and refit as necessary