Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove electrical connector to flow sensor
Remove connector X20 from PCB

Measurement:

Test 1.
Measure the resistance across X20 connector, pins 7,8 & 16
to a suitable earth connection
Expected resistance greater than 1 Mohm, each pin to earth.
Test 2.
Measure the resistance across pin 7 connector X20 to pin 16 of the same connector.
Repeat test for pin 8 to pin 16.
Expected resistance greater than 1 Mohm.
Note.
1. PCB connector numbers can be found on the board.
2. Ensure a good connection is made or misdiagnosis will occur.