Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove electrode assembly from boiler
Disconnect lead from the PCB
Disconnect lead from the PCB
Measurement:
Thoroughly check the spark electrode for wear, contamination,
cracks and damage, confirm electrode gap is 4mm +0.5mm.
Measure the resistance of the electrode and lead, from the tip of
the electrode to the lead connector.
Also visually inspect the condition of the lead.
Expected resistance approx. 5Kohms.
cracks and damage, confirm electrode gap is 4mm +0.5mm.
Measure the resistance of the electrode and lead, from the tip of
the electrode to the lead connector.
Also visually inspect the condition of the lead.
Expected resistance approx. 5Kohms.

Isolate as per TOPs P4
and refit as necessary