FAULT CODES
None
| Fault code | Cause | Action (click on appropriate action) |
| 0A | CO limiter (if installed) has responded. CO concentration too high. | Check the heating system. Remove the cause of escaping CO |
| 0A | Gas pressure switch (if installed) has responded. Gas pressure too low. | Check gas supply |
| 0C | Mains voltage too low | Check the power supply. |
| 10 | Short circuit, outside temperature sensor | Check the outside temperature sensor and lead |
| 18 | Lead break, outside temperature sensor | Check the outside temperature sensor and lead |
| 30 | Short circuit, boiler water temperature sensor | Check boiler water temperature sensor |
| 38 | Lead break, boiler water temperature sensor | Check boiler water temperature sensor |
| 51 | Short circuit, outlet temperature sensor | Check sensor |
| 52 | Short circuit, flow sensor | Check connections, lead & sensor |
| 59 | Lead break, outlet temperature sensor | Check sensor |
| 5 A | Lead break, flow sensor | Check connections, lead & sensor |
| A3 | Flue Gas Sensor Check Failed | Check connections, lead, fitment & sensor |
| b0 | Short circuit, flue gas temperature sensor | Check sensor |
| b8 | Lead break, flue gas temperature sensor | Check sensor |