Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove 1 connector from overheat stat and make safe
Remove fan control connector from fan assembly and make safe
Remove fan control connector from fan assembly and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure for DC voltage across pin 13 connector X20 and a suitable earth connection.
Expected voltage approximately 7.0 Vdc or greater.
Expected voltage approximately 7.0 Vdc or greater.

Isolate as per TOPs P4
and refit as necessary