Set Appliance State:
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
To set boiler to maximum output follow steps below.
1. Press MODE.
2. Press up / down buttons until "SERV" is displayed.
3. OK to confirm, "OFF" appears on the display.
4. Use up / down buttons to select the burner output (100 = max output), see table 1.
5. Confirm your setting with OK, boiler will ignite & run at maximum output.
6. To terminate test mode:
Press MODE.
Use up / down until " SERV" flashes.
OK to confirm, the selected value flashes.
Press down until OFF flashes.
OK to confirm, when "SERV" disappears, test mode is terminated.
1. Press MODE.
2. Press up / down buttons until "SERV" is displayed.
3. OK to confirm, "OFF" appears on the display.
4. Use up / down buttons to select the burner output (100 = max output), see table 1.
5. Confirm your setting with OK, boiler will ignite & run at maximum output.
6. To terminate test mode: