Set Appliance State:

Gas Off
Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
Attach U gauge to gas inlet pressure test point
Gas On
WARNING! - Mains voltage is expected during test follow
TOPs P4 live testing procedure
Mains Power On

Observation:

If required, reset boiler, press mode and ok for 2 seconds.
Allow self-check to complete and ignition sequence to commence.
Observe the U Gauge throughout the ignition cycle, during the sparking stage of the ignition sequence there should also be a noticeable dip from standing to working pressure as the gas valve opens.
Inlet pressure should remain above 17.4mb (N.G.) or 25mb (L.P.G) throughout the ignition sequence.