Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to the incoming connections at the PCB
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between the FR pin at the external frost protection connector (turquoise) and the neutral on the incoming mains connector.
Is mains voltage measured?
Note:
The appearance and layout of the incoming mains connector can vary depending on the PCB version, utilise the appropriate neutral, the frost protection connector remains the same.
Is mains voltage measured?
Note:
The appearance and layout of the incoming mains connector can vary depending on the PCB version, utilise the appropriate neutral, the frost protection connector remains the same.

Isolate as per TOPs P4
and refit as necessary