Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Unplug mains connection from underneath spark generator
Measurement:
Test 1:
Measure the resistance between the two rearmost spades at the spark generator.
Resistance should be greater than 1M Ohm (or O.L on meter).
Test 2:
Measure the resistance between the two outer spades at the spark generator.
Resistance should be greater than 1M Ohm (or O.L on meter).
Are the resistances measured as expected?
Measure the resistance between the two rearmost spades at the spark generator.
Resistance should be greater than 1M Ohm (or O.L on meter).
Test 2:
Measure the resistance between the two outer spades at the spark generator.
Resistance should be greater than 1M Ohm (or O.L on meter).
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary