Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove both wires from the safety thermostat
Measurement:
Measure the resistance between the terminals of the safety thermostat.
Expect continuity / zero resistance.
Is the resistance measured as expected?
Note:
Image shows the safety thermostat removed for clarity but the test is carried out with the safety thermostat in situ attached to the primary heat exchanger.
Expect continuity / zero resistance.
Is the resistance measured as expected?
Note:
Image shows the safety thermostat removed for clarity but the test is carried out with the safety thermostat in situ attached to the primary heat exchanger.

Isolate as per TOPs P4
and refit as necessary