Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Attach U gauge to the burner pressure test point
Remove wires from modureg and make safe
Remove wires from modureg and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
During the sparking stage of the ignition cycle
measure the burner pressure.
It should be set as per the table.
Is the ignition burner pressure set correctly?
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.
measure the burner pressure.
It should be set as per the table.
Is the ignition burner pressure set correctly?
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.
Isolate as per TOPs P4
and refit as necessary