Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the microswitch from the hydroblock
Remove the wires from the terminals
Remove the wires from the terminals
Measurement:
Measure the resistance between the 2 outer terminals of the microswitch (do not press the microswitch the pin must be released).
Expect continuity/zero resistance.
Is the resistance measured as expected?
Expect continuity/zero resistance.
Is the resistance measured as expected?

Isolate as per TOPs P4
and refit as necessary