Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector J5 from the PCB
Measurement:
Test 1:
Measure the resistance between pins 3 and 4 on connector J5.
Expect approximately 125 ohms.
Test 2:
Measure the resistance between pin 3 on connector J5 and a suitable earth.
Expect a resistance of 1 Mohm or greater.
(O.L is acceptable because this is greater than 1 Mohm)
Are the resistances measured as expected?
Measure the resistance between pins 3 and 4 on connector J5.
Expect approximately 125 ohms.
Test 2:
Measure the resistance between pin 3 on connector J5 and a suitable earth.
Expect a resistance of 1 Mohm or greater.
(O.L is acceptable because this is greater than 1 Mohm)
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary