Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove both orange wires from the modureg
Measurement:
Test 1:
Measure the resistance between the two terminals of the modureg.
Expect approximately 125 Ohms.
Test 2:
Measure the resistance between one of the terminals of the modureg and a suitable earth.
Expect a resistance of 1 Mohm or greater.
(O.L is acceptable because this is greater than 1 Mohm)
Are the resistances measured as expected?
Measure the resistance between the two terminals of the modureg.
Expect approximately 125 Ohms.
Test 2:
Measure the resistance between one of the terminals of the modureg and a suitable earth.
Expect a resistance of 1 Mohm or greater.
(O.L is acceptable because this is greater than 1 Mohm)
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary