Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove the cover from the pump assembly
Remove the wires from the pump assembly
Remove the wires from the pump assembly
Measurement:
Test 1:
Measure the resistance between the live and neutral terminals of the pump assembly.
Expect approximately 160 ohms or greater.
Test 2:
Measure the resistance between the live and earth terminals of the pump assembly.
Expect a resistance of 1 Mohm or greater.
(O.L is acceptable because this is greater than 1 Mohm)
Are the resistances measured as expected?
Measure the resistance between the live and neutral terminals of the pump assembly.
Expect approximately 160 ohms or greater.
Test 2:
Measure the resistance between the live and earth terminals of the pump assembly.
Expect a resistance of 1 Mohm or greater.
(O.L is acceptable because this is greater than 1 Mohm)
Are the resistances measured as expected?

Isolate as per TOPs P4
and refit as necessary