Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Attach U gauge to burner pressure test point
Remove 1 wire from the modureg and make safe
Remove 1 wire from the modureg and make safe
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow the burner to ignite.
Measure the minimum burner pressure,
it should be as per the table.
Is the minimum burner pressure correctly set?
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.
Measure the minimum burner pressure,
it should be as per the table.
Is the minimum burner pressure correctly set?
Note:
When pressure gauge is removed the pressure test point should be tightened and checked for gas tightness.