Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove both orange wires from DHW demand microswitch
Boiler switch in standby position
Boiler switch in standby position
Measurement:
Hot Water tap OFF.
Resistance across outer terminals of microswitch = open circuit.
Hot water tap ON.
Resistance across outer terminals of microswitch = short circuit.
Note:
The centre terminal on Switch is unused.
Resistance across outer terminals of microswitch = open circuit.
Hot water tap ON.
Resistance across outer terminals of microswitch = short circuit.
Note:
The centre terminal on Switch is unused.

Isolate as per TOPs P4
and refit as necessary