Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Gain access to PCB (use Insulation Mat as required)
Boiler Switch in ON position
Central Heating switch in OFF (central) position
Boiler Switch in ON position
Central Heating switch in OFF (central) position
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Measurement:
Measure the mains voltage across connector PL3 connection 3 (brown) and connection 5 (blue) wires of GV1 & 2 at full sequence board.
Note:
Boiler may go to lockout, switch off power and press reset button to cancel lockout.
Voltage to the gas valves ceases when lockout occurs.
Note:
Boiler may go to lockout, switch off power and press reset button to cancel lockout.
Voltage to the gas valves ceases when lockout occurs.

Isolate as per TOPs P4
and refit as necessary