Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector PL6 at the PCB
Measurement:
Test 1:
Measure the resistance across the brown and blue wires at PL6.
Resistance should be approximately 75 Ohms.
Test 2:
Measure the resistance across the orange and blue wires at PL6.
Resistance should be approximately 32 Ohms.
Test 3:
Measure the resistance across the yellow wires at PL6.
Resistance should be approximately 1.2 Ohms.
Note:
Ensure you consider the resistance of the fused probes when carrying out this test, especially on test 3.
Measure the resistance across the brown and blue wires at PL6.
Resistance should be approximately 75 Ohms.
Test 2:
Measure the resistance across the orange and blue wires at PL6.
Resistance should be approximately 32 Ohms.
Test 3:
Measure the resistance across the yellow wires at PL6.
Resistance should be approximately 1.2 Ohms.
Note:
Ensure you consider the resistance of the fused probes when carrying out this test, especially on test 3.

Isolate as per TOPs P4
and refit as necessary