Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Turn Hot Water Tap On
Boiler Switch in ON position
Central Heating switch in OFF (central) position
Turn gas control knob to main gas position
Slacken the manual restart nut and take precautions to ensure any water released is safely contained
Central Heating switch in OFF (central) position
Turn gas control knob to main gas position
Slacken the manual restart nut and take precautions to ensure any water released is safely contained
Gas On; Pilot On
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Turn on hot water tap.
After main burner has ignited, turn off hot water tap and confirm water pump continues to run.
Note:
Do not take noise or vibration as an indication of operation.
After main burner has ignited, turn off hot water tap and confirm water pump continues to run.
Note:
Do not take noise or vibration as an indication of operation.