Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove connector CN2 from the interface PCB
Remove the connection from the pump assembly and position in the orientation shown (follow instructions on the connector)

Measurement:

Measure the resistance between connector CN2 and the pump connector as below.
Connector CN2Pump connector
Pin 1 (Red)Pin 3
Pin 2 (Black) Pin 2
Pin 3 (Blue)Pin 1
Pin 4 (Brown)Pin 4

Expect continuity on each test.
Also visually inspect the condition of the harness for general condition and any signs of damaged insulation.