Set Appliance State:
Turn Hot Water Tap On
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure the DC voltage between the Blue wire at the fan DC connector (4 wire) and a suitable earth.
Expect approximately 2 - 4 VDC when the fan is running.
Expect approximately 2 - 4 VDC when the fan is running.

Isolate as per TOPs P4
and refit as necessary