Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove connector CN1 from the main PCB
Measurement:
Measure the resistance between the pins on CN1 and the terminals on the incoming mains terminal block as listed in the table below:
Expect continuity on each test.
Also visually inspect the harness for general condition and any signs of damaged insulation.
| Connector CN1 | Incoming mains terminal strip | Pin 4 (Brown) | Live (marked L) |
| Pin 3 (Blue) | Neutral (marked N) |
| Pin 1 (Yellow/Green) | Earth |
Expect continuity on each test.
Also visually inspect the harness for general condition and any signs of damaged insulation.

Isolate as per TOPs P4
and refit as necessary