Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Gain access to PCB (use Insulation Mat as required)
NO demands
NO demands
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure the voltage between pin 1 (Black) and pin 2 (White) on connector CN10.
Voltage should conform approximately to the table below:
Note:
Pressure should be set at approximately 0.5 - 1.5 bar.
Voltage should conform approximately to the table below:
| System pressure | Voltage dc | 0 bar | 0.3 |
| 1 bar | 2.3 |
| 2 bar | 3.2 |
| 3 bar | 4.7 |
Note:
Pressure should be set at approximately 0.5 - 1.5 bar.

Isolate as per TOPs P4
and refit as necessary