Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove connector CN11 from the main PCB

Measurement:

Measure the resistance between pin 1 (Black) and pin 2 (Black)
The resistance depends on temperature and should conform to the table below:
Temperature °CResistance in Kohms
10-2015.0 - 12.0
20-30 12.0 - 8.0
30-40 8.0 - 5.0
40-505.0 - 3.5
50-603.5 - 2.5
60-702.5 - 1.7

Note:
To check the calibration of the thermistor the area directly around it should be measured using a temperature probe.