Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Remove connector from pump assembly
(follow instructions on the connector)

Measurement:

Test 1: Measure the resistance between the pump terminals as per the table below:
TerminalsResistance (Ohms)
1 - 4110
1 - 6 215
2 - 30
2 - 5230
3 - 5230
4 - 6110

Resistances should conform to the table above.
Test 2: Measure the resistance between each of the pumps terminals and earth.
Expect open circuit for each test.