Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove Harness from Gas Valve
Remove connector X6 from PCB
Remove connector X6 from PCB
Measurement:
Test resistance of the wire. The Neutral splits in two at gas valve plug so must be tested on both.
The gas Valve connector is numbered 1 to 5 from top to bottom
3 & Live (Brown on X6 Plug).
then 1 & Neutral (Blue on X6 Plug).
and 4 & Neutral (Blue on X6 Plug).
Expect short circuit
The gas Valve connector is numbered 1 to 5 from top to bottom
3 & Live (Brown on X6 Plug).
then 1 & Neutral (Blue on X6 Plug).
and 4 & Neutral (Blue on X6 Plug).
Expect short circuit

Isolate as per TOPs P4
and refit as necessary