Set Appliance State:
Gas Off
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
Remove screw from middle of pump (use tray to catch any water)
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Observation:
Allow pump to run. Check pump is spinning. Then turn power off. Watch the pump, does it stop spinning within 2 seconds.
Or does it continue to spin longer than 2 seconds indicating that the impellor is loose.
Or does it continue to spin longer than 2 seconds indicating that the impellor is loose.
Isolate as per TOPs P4
and refit as necessary