Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove Connector X6a from PCB
Remove Capacitor/plug from Pump
Remove Capacitor/plug from Pump
Measurement:
Test 1:
Measure the resistance between pin 4 on connector X6a and pin 4 on the pump connector
Expect continuity / zero resistance.
Test 2:
Measure the resistance between pin 5 on connector X6a and pin 1 on the pump connector
Expect continuity / zero resistance.
Also visually inspect the condition of the harness and its connectors.
Are the resistances measured as expected and is the harness in good condition?
Measure the resistance between pin 4 on connector X6a and pin 4 on the pump connector
Expect continuity / zero resistance.
Test 2:
Measure the resistance between pin 5 on connector X6a and pin 1 on the pump connector
Expect continuity / zero resistance.
Also visually inspect the condition of the harness and its connectors.
Are the resistances measured as expected and is the harness in good condition?

Isolate as per TOPs P4
and refit as necessary