Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
On/Off switch ON
Attach temperature clamps as indicated by the red arrows
Attach temperature clamps as indicated by the red arrows
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Observation:
Allow fan to run and boiler to fire and allow system to reach a reasonable operating temperature.
Using telegan temp clamps measure the temperature of the flow and return pipes close to the combustion chamber in the boiler and ascertain temperature difference between flow and return.
Expected differential approx between 11°C and 20°C.
Click on your observation:
1. DIFFERENTIAL OK BUT LOW OR EXCESSIVE TEMPERATURES
2.DIFFERENTIAL NOT OK NOISE LOCAL BOILING
3. DIFFERENTIAL OK HEATING OPERATING SATISFACTORY
Using telegan temp clamps measure the temperature of the flow and return pipes close to the combustion chamber in the boiler and ascertain temperature difference between flow and return.
Expected differential approx between 11°C and 20°C.
Click on your observation:
1. DIFFERENTIAL OK BUT LOW OR EXCESSIVE TEMPERATURES
2.DIFFERENTIAL NOT OK NOISE LOCAL BOILING
3. DIFFERENTIAL OK HEATING OPERATING SATISFACTORY