Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Gain access to PCB (use Insulation Mat as required)
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Test 1:
Hot water tap OFF
Measure the DC voltage between Pin 5 (White)
and Pin 6 (Blue) on connector X2
Expect either 5 or 0 VDC.
(Initial voltage may vary due to the hall sensor position)
Test 2:
Hot Water Tap ON, flow rate approx. 3 litres/min
Measure the DC voltage between Pin 5 (White)
and Pin 6 (Blue) on connector X2
Expect approximately 4.3 VDC.
Note:
Voltage may fluctuate slightly on test 2.