Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
DHW Demand
Gain access to PCB (use Insulation Mat as required)
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Measure the AC volts at the fan on the plug X7 on the PCB from the live to neutral.
Expected voltage should be between 160v and 240v.
Note:
Ensure a good connection is made.
Expected voltage should be between 160v and 240v.
Note:
Ensure a good connection is made.

Isolate as per TOPs P4
and refit as necessary