Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect wires to the fan
Measurement:
Test 1:
Measure the resistance across the two fan terminals
(where the Live and Neutral wires were connected).
Resistance should be approximately 25 - 50 Ohms.
Test 2:
Measure the resistance between each
fan terminal, in turn, to the fan earth point.
Resistance on each test should be
greater than 1M Ohm.
Measure the resistance across the two fan terminals
(where the Live and Neutral wires were connected).
Resistance should be approximately 25 - 50 Ohms.
Test 2:
Measure the resistance between each
fan terminal, in turn, to the fan earth point.
Resistance on each test should be
greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary