Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect connector J2 from the ignition PCB
Measurement:
Test 1:
Measure the resistance between pin 5 (blue) and pin 4 (brown) on J2 connector.
Resistance should be approximately 25 - 50 Ohms.
Test 2:
Measure the resistance between pin 4 (brown) wire on J2 connector to a suitable earth point.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance between pin 5 (blue) wire on J2 connector to a suitable earth point.
Resistance should be greater than 1M Ohm.
Measure the resistance between pin 5 (blue) and pin 4 (brown) on J2 connector.
Resistance should be approximately 25 - 50 Ohms.
Test 2:
Measure the resistance between pin 4 (brown) wire on J2 connector to a suitable earth point.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance between pin 5 (blue) wire on J2 connector to a suitable earth point.
Resistance should be greater than 1M Ohm.

Isolate as per TOPs P4
and refit as necessary