Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
CH Temperature Control to MAX
Insert temperature probe to flue gas test point, ensure
it is fitted securely to prevent escape of flue gases
Insert temperature probe to flue gas test point, ensure
it is fitted securely to prevent escape of flue gases
| WARNING! - Mains voltage is expected during test follow TOPs P4 live testing procedure |
Observation:
Allow burner to ignite and establish.
Monitor flue gas temperature as appliance reaches temperature.
Does the flue gas temperature remain approx. 100°C or lower?
Note:
To reduce the time taken for this test you may wish to turn off some radiators.
Monitor flue gas temperature as appliance reaches temperature.
Does the flue gas temperature remain approx. 100°C or lower?
Note:
To reduce the time taken for this test you may wish to turn off some radiators.