Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to Resistance Set meter to measure resistance
Disconnect plug marked JP5

Measurement:

Test 1:
With DHW temperature selector set to maximum,
measure the resistance across the blue wire (connection 4),
and the black wire (connection 5).
Resistance measured should be approximately 11 kOhms.
Turn CH temperature selector to minimum.
Resistance should reduce to less than 100 Ohms.
Test 2:
With DHW temperature selector set at minimum, measure the resistance across the white wire (connection 6), and the black wire (connection 5).
Resistance measured should be approximately 11 kOhms.
Turn DHW temperature selector to maximum.