Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Disconnect plug connector (marked JP11) from PCB
Remove the microswitch from the top of the diverter valve
Remove the microswitch from the top of the diverter valve
Measurement:
Check resistance across connections 3 & 4 (Brown & Blue wires)
Expect short circuit.
Now depress the microswitch.
Expect open circuit.
Note:
Care should be taken that probe tips do not touch each other when taking measurement as a false reading will be given.
Expect short circuit.
Now depress the microswitch.
Expect open circuit.
Note:
Care should be taken that probe tips do not touch each other when taking measurement as a false reading will be given.

Isolate as per TOPs P4
and refit as necessary