Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove 1 connector from the left hand switch
(violet/black and brown leads)
(violet/black and brown leads)
Measurement:
Measure the resistance across the on/off switch.
Test 1
With switch in its out position (OFF) - expect open circuit.
Test 2
With switch in its in position (ON) - expect short circuit.
Note:
Older models will have 3 connections on the on/off switch with an additional red wire from the main switch to the flame failure switch, it does not affect this test.
Test 1
With switch in its out position (OFF) - expect open circuit.
Test 2
With switch in its in position (ON) - expect short circuit.
Note:
Older models will have 3 connections on the on/off switch with an additional red wire from the main switch to the flame failure switch, it does not affect this test.

Isolate as per TOPs P4
and refit as necessary