Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Turn Hot Water Tap On
DHW temperature control to maximum
CH temperature control to minimum
Remove the vent plug from the pump
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Observation:

Remove the vent screw from the front of the pump and observe the spindle.
CAUTION: Water may be emitted from the end of the pump, be sure to protect the work area while undertaking this test.
Does the pump run?
Note:
Do not take sound or vibration as indication pump is running.