Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
Remove ignition PCB from the gas valve
Disconnect leads to modulating solenoid
Disconnect leads to modulating solenoid
Measurement:
Test 1:
Measure the resistance across pin 1 and 5 of the gas valve main solenoid.
Resistance should be approximately 4.2kOhms.
Test 2:
Measure the resistance across pin 1 and 3 of the gas valve main solenoid.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance across the two pins of gas valve modulating solenoid.
Resistance should be approximately 115 Ohms.
Measure the resistance across pin 1 and 5 of the gas valve main solenoid.
Resistance should be approximately 4.2kOhms.
Test 2:
Measure the resistance across pin 1 and 3 of the gas valve main solenoid.
Resistance should be greater than 1M Ohm.
Test 3:
Measure the resistance across the two pins of gas valve modulating solenoid.
Resistance should be approximately 115 Ohms.

Isolate as per TOPs P4
and refit as necessary