Set Appliance State:
| Isolate Mains Power to appliance as per TOPs P4 |
CH Demand
CH temperature control to maximum
DHW temperature control to minimum
CH temperature control to maximum
DHW temperature control to minimum
Attach temperature clamps to flow and return pipes
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Observation:
Place a demand for heating and allow the boiler to heat for a few min.
Using temperature clamps for the FGA (Flue Gas Analyser) measure the temperature on the primary flow and return pipes under the boiler, there should be a differential of approx. 10-15°C between the flow and return.
Using temperature clamps for the FGA (Flue Gas Analyser) measure the temperature on the primary flow and return pipes under the boiler, there should be a differential of approx. 10-15°C between the flow and return.