Set Appliance State:
Mains Power Off
DHW Demand
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
DHW Selector in Maximum (+) position
CH Selector in Minimum (-) position
ON/OFF Switch in ON position
| WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure |
Measurement:
Boiler ON/OFF switch ON.
Measure on connector M1 the voltage across the brown lead (Live) and blue (Neutral) on the PCB.
Measure on connector M1 the voltage across the brown lead (Live) and blue (Neutral) on the PCB.

Isolate as per TOPs P4
and refit as necessary