Set Appliance State:

Isolate Mains Power to appliance as per TOPs P4
Set Multimeter to DC Volts Set meter to measure DC Volts
Turn Hot Water Tap On
DHW temperature control to maximum
CH temperature control to minimum
Unplug the ignition PCB from the gas valve and turn the PCB around to expose
the rear connecting pins
Use insulation mat as required
WARNING! Mains voltage is expected during test, follow TOPs P4 live testing procedure
Mains Power On

Measurement:

Allow the fan to run and the ignition sequence to commence.
Measure voltage between the top and bottom pins on the rear of the ignition PCB.
Expected voltage approximately 230V DC.